Hand-held ultrasonic transducer flow meter/portable ultrasonic flow meter
Flow velocity: 0.1 - 12m/s
Accuracy: 0.2
Hand-held ultrasonic transducer flow meter/flow indicator/flow sensor/flow transmitter
/portable ultrasonic flowmeter
What is Ultrasonic Flow Meter?
Ultrasonic flow meter is designed to measure the velocity of liquid within a closed conduit. It uses the well-known transit-time measurement principle, plus our proprietary signal processing and ultrasonic transcribing technologies.
A pair of ultrasonic transducers is mounted on the pipe upstream and down stream respectively. Each transducer serves as both ultrasonic transmitter and receiver. The main unit operates by alternately transmitting and receiving a coded burst of sound energy between the two transducers. The transit-times in the upstream direction as well as in the downstream direction are measured. The difference of the two transit times is directly and exactly related to the velocity and the liquid in the pipe.
Features of Ultrasonic Flow Meter
- Energy rate and total consumption measurement
- Non-intrusive clamp-on technology. Easy and economical installation
- No moving parts to worn out. Long life span. No maintenance
- High accuracy. Thermal energy custody transfer performanceWide flow measurement range, bi-directional
- Built-in totalizer, batch controllers and task scheduler
- Isolated RS-485 interface. Supports MODBUS protocol
- Abundant inputs/outputs, such as 4-20mA output, relay output, pulse output, alarm output, etc
- Easy to use and set up. Self-explanatory menu-driven programming
- NEMA 4X (IP65) Weather-resistant enclosure Low-power consumption, less than 1.5Watts
- Suitable for virtually any liquid heating/cooling systems such as HVAC, office buildings, apartment complexes, condominiums, solar heating systems and geothermal systems.
Technical Specifications of Ultrasonic Flow Meter
Main Unit2 line x 20 character LCD with backlight Working temperature: -25~60°C
Mini thermal printer with 24 line character output
4×4+2 pushbutton keypad
RS-485 interface for networking
Ultrasonic flow meter Transducer OptionsTS-1: small size transducer (magnetic) for pipe size: DN15~100mm, liquid temperature ≤110°C
TM-1:medium size transducer (magnetic) for pipe size: DN50~1000mm, liquid temperature ≤110°C Ultrasonic Transducer options
TL-1: Large size transducer (magnetic) for pipe size: DN300~6000mm, liquid temperature ≤110°C
Temperature TransducerThree wire PT100 platonic resistance, measuring range: -50~+180°C measuring accuracy:100°C, 0.8°C , the temperature difference ≤0.1°C
Liquid typesWater, sea water, industrial sewage, acid and alkali liquid, various oils etc. liquid which can transmit sound wave.
FlowVelocityRange0~±30m/s
AccuracyBetter than ±1%
Power SupplyBuilt-in rechargeable Ni-MH battery (for 20 hours operation) or AC 220V
Power Consumption1.5W
ChargingIntelligent charging with AC 220V; After charging sufficiently, it automatically stop and display green light
WeightNet weight: 2.5kg (main unit)
RemarksWith a high strength carrying case suitable for normal and harsh environment
Applications of Ultrasonic Flow Meter
- Water Treatment
- Pump Testing
- Paper & Pulp
- Effluent Treatment Plants
- Waste Water & Sewerage
- Food & Diary Processing
- Chemical Process Plants
Optional flow Sensor
S1H Small and High Temperature Resistance type sensor (For N15-100)
Middle and high Temperature resistance type sensor (For DN50-700mm)
S1 series Standard Small-type flow sensor(magnetism)
(For DN15-100mm)
M1 series Standard Mid-type flow sensor(magnetism)
(For DN50-700mm)
L1 series Standard Large-type flow sensor
(For DN300-6000)
Linearity |
0.5% |
Repeatability |
0.2% |
Accuracy |
±1% of reading at rates>0.2 mps |
Response Time |
0-999 seconds, user-configurable |
Velocity |
±32 m/s |
Pipe Size |
20mm-6000mm |
Rate Units |
Meter, Feet, Cubic Meter, Liter, Cubic Feet, USA Gallon, Imperial Gallon, Oil Barrel, USA Liquid Barrel, Imperial Liquid Barrel, Million USA Gallons. User configurable. |
Totalizer |
7-digit totals for net, positive and negative flow respectively |
Liquid Types |
Virtually all liquids |
Security |
Setup values Modification Lockout. Access code needs unlocking |
Display |
4x8 Chinese characters or 4x16 English letters |
Communication Interface |
RS-232C, baud-rate: from 75 to 57600. Protocol made by the manufacturer and compatible with that of the FUJI ultrasonic flow meter. User protocols can be made on enquiry. |
Transducers |
Model M1 for standard, other 3 models for optional |
Transducer Cord Length |
Standard 2x10 meters, optional 2x 500 meters |
Power Supply |
3 AAA Ni-H built-in batteries. When fully recharged it will last over 10 hours of operation. 100V-240VAC for the charger |
Data Logger |
Built-in data logger can store over 2000 lines of data |
Manual Totalizer |
7-digit press-key-to-go totalizer for calibration |
Housing Material |
ABS |
Case Size |
100x66x20mm |
Handset Weight |
514g (1.2 lbs) with batteries |