Capacitance Level / Differential Pressure Transmitter Sensor
Contact Supplier
Product Highlights
- Wide Measuring Range: Capable of measuring pressure from 100 Pa to 40 MPa with a range ratio of 50:1.
- Customizable Materials: Isolation diaphragms available in 316L SS, Hastelloy, Tantalum, or Monel for corrosion resistance.
- HART Protocol Support: Features digital communication via HART protocol for remote configuration and monitoring.
- IP67 Protection Rating: Robust IP67 rating protects against dust and water ingress for harsh industrial environments.
- Flexible Output Signals: Provides 4-20mA analog output or digital signals compatible with various control systems.
- Versatile Applications: Suitable for measuring pressure, differential pressure, liquid level, flow, and density of liquids, gases, or steam.
Product Attributes
- Customization
- Available
- Type
- Capacitive Pressure Sensor
- Component
- SemiConductor Type
- Model NO.
- 3051, 3351 pressure sensor
- For
- Capacitive Pressure Transmitter
- Output Signal Type
- Anolog or Digital
- Production Process
- Normal Wirewound
- Material
- Stainless Steel
- Thread Type
- NPT or Flanged
- Wiring Type
- Two-Wire or Four-Wire
- Measuring Medium
- Steam or Liquid
- IP Rating
- IP67
- Certification
- ISO
- Customized
- Customized
- Measuring Instrument
- Pressure, Liquid Level
- Medium
- Liquid, Air, Steam
- Display
- Digital
- Function
- Local Indication Type
- Accuracy
- 0.2%/0.5%
- Indicating Pressure Reference
- General Pressure Gauge
- Application
- Industrial, Industrial~
- Structure
- Fluid Column Pressure Gauge
- Connection Type
- Axial
- Measuring Range
- Low-Pressure Gauge
- Transport Package
- Wooden Case or Carton
- Specification
- CE, SGS, ISO
- Trademark
- Tianjin U-ideal Instrument
- Origin
- Tianjin, China
- HS Code
- 902620109
- Production Capacity
- 6000 PCS/Month
- Package Size
- 20.00cm * 30.00cm * 50.00cm
- Package Gross Weight
- 10.000kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of Capacitance Level / Differential Pressure Transmitter Sensor
Find Similar Products
Product Description
Pressure based transmitter Main products:
Pressure transmitter
n T20 series pressure transmitter/pressure sensor
n T51GP pressure transmitter
n T61GP pressure transmitter/pressure sensor
n T61TGP pressure transmitter
n T61AP absolute pressure transmitter
Differential Pressure transmitter
n T51DP Differential pressure transmitter / pressure sensor
n T51HP high hydrostatic differential pressure transmitter
n T51DR micro differential pressure transmitter
n T51DP/GP remote sensor differential pressure transmitter
n T61DP differential pressure transmitter
n T61HP high hydrostatic differential pressure transmitter
n T61DR micro pressure transmitter / pressure sensor
n T61C
n T61DP/GP remote sensor differential pressure transmitter
Liquid Level Transmitter
n T20L drop-in cable level transmitter
n T20L insert rod type level transmitter
n T20Y flanged level transmitter
n T20D press-guiding level transmitter
n T20M diaphragm level transmitter
n T51LT flanged level transmitter
n T61LT flanged level transmitter
n T61Y pressure vessel level transmitter
n T61W sanitary type pressure sensor
Flow Transmitter
n T51 flow transmitter
n T61 flow transmitter
n T61S flow transmitter
n T61C flow transmitter
UI-P61 Series Capacitance type intelligent transmitter
UI - P61 Ordinary structure differential pressure, gage pressure and absolute pressure transmitter
l Accuracy 0.1%; Ratio: 50:1
l Measure pressure Range from 100 Pa to 40 MPa
l Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE.
l Light, small, easy to install
UI - P61C Integrated structure differential pressure, gage pressure and absolute pressure transmitter
l Accuracy 0.1%; Ratio: 50:1
l Measure pressure Range from 100 Pa to 40 MPa
l Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE.
l Flanged integrated structure, Good design is durable, no leakage;
l Light, small, easy to install
UI-P61T Directly mount gauge pressure, absolute pressure transmitter
l Accuracy 0.1%; Ratio: 50:1
l Measure pressure Range from 100 Pa to 40 MPa
l Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel.
l Light, small, easy to install;
UI-P61 LT Level transmitter
l Accuracy 0.2%; Ratio: 15:1
l Flat diaphragm or 50mm, 100mm, 150mm, 200mm inset diaphragm.
l Various filling liquid to suit strict temperature.
l Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE.
UI-P61 Remote pressure /differential pressure transmitter
l Accuracy 0.2%; Ratio: 15:1
l Flat diaphragm or 50mm, 100mm, 150mm, 200mm inset diaphragm.
l Suit stricter temperature.
l Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE.
UI-P61W sanitary pressure transmitter
l Accuracy 0.2%; Range ratio: 15:1
l Various process mounting type..
l Various filling liquid to suit various sanitary conditions.
l Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE.
UI-P61Y pressurized container special using drop-in type level transmitter
Accuracy 0.2%; Range ratio: 15:1
Various process mounting type.
Various filling liquid to suit strict temperature.
Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE.
U-ideal´s 3351(&1151) 3051DP differential pressure transmitter provides a kind of reliable measuring way. It is used for measuring differential pressure (or pressure), level, density of liquid, gas or steam and convert the value of above into current signal output or digital protocol output. The pressures are directly applied to the isolating diaphragm that provide isolation and resistance against process fluid corrosion. Being microprocessor based, the electronic circuit is extremely versatile and accurate. Combined with the sensor precision, it provides the high accuracy and range ability. Transmitter performance is improved by continuous monitoring of the sensor temperature and corresponding corrections. A local display permits easy reading and writing of data.
The Model 3351 design is offered for Differential Pressure (DP), Gage Pressure (GP) and Absolute Pressure (AP) measurements. The Model 3351utilizes capacitance sensor technology for DP measurements. The major components of the Model 3351 is the sensor module and the electronics housing.
| Model | Transmitter Type(Single selection) | DP | HP | GP | AP | ||
| 3051DP | Differential Pressure transmitter | . | - | - | - | ||
| 3051HP | High pressure Differential pressure transmitter | - | . | - | - | ||
| UIP-T62GP | Gauge Pressure | - | - | . | - | ||
| 3051AP | Absolute Pressure | - | - | - | . | ||
| Code | Pressure Measure range(URL)(Single selection) | DP | HP | GP | AP | ||
| 3 | 1.3~7.5kPa | . | . | . | - | ||
| 4 | 6.2-37.4kPa | . | . | . | . | ||
| 5 | 31.1-186.8kPa | . | . | . | . | ||
| 6 | 117-690kPa | . | . | . | . | ||
| 7 | 345-2068kPa | . | . | . | . | ||
| 8 | 1170~6890kPa | . | - | . | . | ||
| 9 | 3480~20680kPa | - | - | . | - | ||
| 0 | 6890~41370kPa | - | - | . | - | ||
| Code | Transmitter output (single selection) | DP | HP | GP | AP | ||
| E | 4-20mA,Linear, Analog /damping adjustable | . | . | . | . | ||
| N | 4-20mA, digit intelligent type | . | . | . | . | ||
| S | 4-20mA,intelligent, HART protocal | . | . | . | . | ||
| Code | flange & Joints | drain/vent | diaphragm | DP | HP | GP | AP |
| 22 | 316SS | 316SS | 316L SS | . | . | . | . |
| 23 | 316SS | 316SS | hastelloy C | . | . | . | . |
| 24 | 316SS | 316SS | Monel Alloy | . | . | . | . |
| 25 | 316SS | 316SS | tantalum | . | . | . | . |
| 33 | hastelloy C | hastelloy C | hastelloy C | . | . | . | . |
| 35 | hastelloy C | hastelloy C | tantalum | . | . | . | . |
| 44 | Monel Alloy | Monel Alloy | Monel Alloy | . | . | . | . |
| Code | Indicator (If don't need local display, don't select) | DP | HP | GP | AP | ||
| M1 | Analog Scale, Linear head, 0-100% scale | . | . | . | . | ||
| M2 | Analog Scale, square root showing, 0~10 scale | . | . | - | - | ||
| M3 | LCD, linear head, 0-100% selectable | . | . | . | . | ||
| Code | Mounting bracket | DP | HP | GP | AP | ||
| B1 | Tube bending plate ( tube outside diameter Φ50~60) | . | . | . | . | ||
| B2 | Plate bending plate | . | . | . | . | ||
| B3 | Tube flat plate ( tube outside diameter Φ50~60) | . | . | . | . | ||
| Code | Release valve | DP | HP | GP | AP | ||
| D0 | Drain valve at the back | . | . | . | . | ||
| D1 | Side Release valve above the pressure chamber | . | . | . | . | ||
| D2 | Side Drain valve at the bottom of the pressure chamber | . | . | . | . | ||
| Code | Low pressure side Flange adaptor | DP | HP | GP | AP | ||
| N | no flange adapter (with 1/4NPT female at flange to connect the press-leading lines) | . | . | . | . | ||
| C1 | 1/2NPT female screw flange adapter, connect pilot pressure joint and welding press-leading tube(stainless steel) | . | . | . | . | ||
| C2 | M20x 1.5 Male screw flange adapter, connect pilot pressure joint and welding press-leading tube(stainless steel) | . | . | . | . | ||
| Code | Explosion-proof (don't select is standard type) | DP | HP | GP | AP | ||
| d | explosion-proof Exd II CT6 | . | . | . | . | ||
| i | Intrinsically safety Exia II CT6 | . | . | . | . | ||
| Typical model: 3051DP 4 S 22 M3 B3 D2 C2 | |||||||
Performance & technique parameter
(Reference conditions: no zero migration, silicone oil filling, 316L diaphragm)
The output signal: 4-20 mA two-wire system;
Accuracy:
Linear output: ±0.1% (to range ratio 1:1}, including linear, variation, the repeatability general error.
Extraction of root output: when the output pressure is 4-100%, is (0.2% of Calibrated range + 0.05% at biggest).
Stability: for DP range code 3, 4, 5, stability is ±0.2% of the highest range. For other range code, stability is ±0.25% of the highest range.
Humidity: 0-100% relative humidity;
Start time: At minimum damping, 2 seconds at most.
Volume drain: <0.16 cm3
Damping: electrical damping is 0 to 32s. In addition, the sensitive element have 0.2s Constant damping time (range 3 is with 0.4 seconds);
Static pressure effect (DP transmitter)
Zero error: If 10 Mpa, zero error is 0.25% of the highest range; for range which code is 3, zero erro is 0.5% of the highest range; zero point can be corrected through the zero adjustment.
Temperature influence:
The zero error at the biggest range:
±0.5% every 56 ºC; total influence include span and zero error, ±1% every 56 ºC; for range which code is 3 in model table, the influence is times of above range;
For the smallest measure range zero error, ±0.5% every 56 ºC; total influence include span and zero error, ±3.5% every 56 ºC; for range code 3 in model selection, the influence is times of above range;
Vibration impact: Frequency is o - 200 HZ, each g is ±0.05% up limit at any direction.
Power supply: < 0.005%/V of calibration range.
Installation position influence: zero drift <0.25 KPa, the error can be eliminated by correction, so without impact to range.
Electromagnetic interference/radio frequency interference: according to SAMA PMC33.1, test from 20-1000 Hz, field intensity can be up to 30V/m.
Standard structure
Wet parts materials
Isolation diaphragm
316L, Hastelloy C - 276, monel or tantalum, each types optional materials, see to the order information table.
Drain/air valve
316L, Hastelloy C - 276, monel. Each type optional material, see to the order information table.
Wet O-rings:
Non-wet parts material:
Liquid filling: Silicon or Inertia fluid
Bolts and flange with bolts: galvanized carbon steel;
Electric shell: Low copper aluminum;
Spraying: polyurethane (PU)
Gauge cover O ring: NBR (nitrile rubber Buna)
Process connection port:
1/4 ~ 18 NPT: Range 3, 4 and 5, flange distance: 54 mm
1/4 ~ 18 NPT: Range 6 and 7, flange center distance: 56 mm
1/4 ~ 18 NPT: Range 8, flange center distance: 57 mm
Range 3, 4 and 5, Flange joint can be rotated, in order to realize the 51 mm,
54 mm or 57 mm center distance.
Electrical connections
1/2~14 NPT or M20X1. 5 conduit entrance; weight: 2.4 kg
Conditions of use
Overall protective performance: IP67
Power supply voltage:
12V - 45VDC intrinsic safety products, power supply should through safety barrier firstly. (Standard is 24 VDC, if no load can work at 12VDC, with LCD header power should be not less than 16 VDC)
Products application environment
Temperature: - 20ºC~+80ºC, storage temperature: - 40ºC - + 104ºC; humidity: 0-90%
Explosion-proof products using environmental conditions:
Temperature: - 20ºC - + 40ºC; relative humidity: 5% ~ 95%.
Atmospheric pressure: 86-106 KPa
Intrinsic safety production matched safety barrier parameters:
Uo ≤28r DC; Io≤30mA
UI-P61 series intelligent pressure / differential pressure transmitter
General introduction:Application:
UI-P61 series pressure/ differential pressure transmitter have many different types which are used to measure differential pressure, flow, gauge pressure, absolute pressure, vacuum degree, liquid level and specific gravity. Read carefully the order instruction table to confirm us the transmitter model, pressure range, signal output type and transmitter's structure materials.
Working principle:
When work, the high and low pressure side diaphragm and filling liquid pass the pressure to the center of filled liquid, the center filled liquid passed the pressure to center diaphragm ofδchamber sensor, and the sensing diaphragm is a tension elastic element, the displacement changed by the differential pressure ( GP gauge pressure transmitter, atmospheric pressure is like exert the pressure on the low pressure side of the sensing diaphragm; AP absolute pressure transducer, low pressure side always keep a reference pressure). The largest displacement of diaphragm is 0.1 mm, and the displacement is proportional to the pressure force. The capacitor plate on both sides sense the diaphragm position. The differential capacitance value between Sensing diaphragm and electrical capacitor plate is transferred into the corresponding current, voltage or digital HART output signal.
PCB module
The transmitter PCB module adopts special using Integrated Circuit (ASICS) and surface sealing technology. When the PCB received the digital signal from sensor diaphragm and coefficient corrected correct the signal and linearizing it. PCB output the digital signal to analog signal output and communicate with Hart operator. Is insert the LCD head to the PCB, then the transmitter can display the pressure unit and percentage unit digital output.
The data configuration
The configuration data stored n the transmitter circuit board EEPRQM permanent storage. So the Transmitter still can save the data even power off. Therefore the transmitter can work immediately once power on.
Digital / Analog converter and signal transmission
Process Variable is stored by data mode. Can be fine corrected and engineering unit converting. Then the corrected data is converted into analog signal output. The HART operator can store the sensor digital signal directly with higher accuracy which don't need digital / analog converting again.
Software function:
HART protocol make user easily to configure, test and set the UI-P61 series transmitter.
Communication Mode
UI-P61 series pressure/differential pressure transmitter adopts HART protocol communication.
The protocol adopts the industrial standard Bell202 frequency shift keying (FSK) technology, superimposed a high frequency signal on the current output signal to realize the remote communication. This technology can make the transmitter communication and output at the same time and without influence the Loop consistency.
The configuration
UI-P61 series pressure/differential pressure transmitter can be easily configured with HART hand operator. The configuration includes two Aspects. First. The transmitter operational parameter Settings, include Settings:
l Zero and span set
l Linear output or square root output
l Damping,
l The engineer unit selection
The second, the informational data of transmitter deposited in the transmitter which to recognize the transmitter and make physical description for the transmitter. These data include:
l Location number: 8 letters, number and characters
l Descriptors: 16 letters, number and characters
l Information: 32 letters, number and characters
l Date & integrated transmitter head installation
l Flange type, and flange material
l Drainage/exhaust valve materials & O ring material
l The remote parts material information
In addition to the above, the software also contains many non users can modify information: the transmitter types, sensor limited, the minimum range, filling liquid, the diaphragm material, diaphragm head serial number and software version number.
Test
UI - P61 series pressure/differential pressure transmitter can do self-inspection consecutively. If problems found, transmitter will activate the users optional analog output alarm, can check the problem with HART hands operator to determine the problem. Transmitter output specific information to the HART operator to help identifying the problem and maintenance immediately. If the operating personal convinced that the problem is come from circuit return, the transmitter can provide the specific output by asking which is for use of loop test.
The specific Settings
Specific Settings for transmitter first time setting and the digital PCB maintenance. It allows fine adjustment to the sensor and the analog output to meet factory pressure standards. In addition, the characteristic function avoid the user accidental or intentional adjusting the setting point of analog output.
Technique information
Medium: Liquid, air or Steam
Output: 4~20mA DC, user can select linearity or square root output digital process variables added to 4~20mA signal. Are available on the HART protocol used on microcomputer.
Power supply
Require outer power supply. Working power is 12~45VDC when transmitter without load.
| Vmin | Vmax | Rmin | Rmax | RL at Power Vs |
| 12V | 45V | 0'Ω | 1650'Ω | R1=(Vs-12)/0.02 |
Span and Zero
Can adjust the Span and Zero through the transmitter or by HART operator remote adjustment.
Zero positive and negative shift
When Zero negative shift, the range low limit must be ≥- URL;
The zero positive shift must be ≤+ URL.
Test range must ≥the minimum span.
Temperature limit
PCB operating temperature: -40 to 80º;
The sensor working temperature: filling silicone oil: -40 to 104ºC
| Filling liquid | Temperature | Specific gravity g/cm |
coefficient of thermal expansion |
viscosity at 25ºC |
| 200# silicon | -40~149ºC | 0.934 | 0.00108 | 9.5 |
| high temperature silicon oil | 15~315ºC | 1.07 | 0.00053 | 44 |
| Inertia oil | -45~205ºC | 1.85 | 0.000864 | 65 |
Humidity limit: 0~100% relative humidity
Volume changing: <0.16cm3
Fault alert
Self-diagnostic function detected the transmitter failure, then analog signal is output by lower than 3.9mA or higher than 21mA to alert user. The high or low alarm signal can be selected by user.
| Electric Level | 4~20mA saturation value | 4~20mA alert valve |
| low | 3.9mA | 3.8mA |
| high | 20.8mA | 21.72mA |
Transmitter protection
Use transmitter protection function can prevent changes the transmitter configuration, including preventing the device zero and span adjustment. Protect function can be set by internal switch.
Over voltage alarm
If the transmitter output a negative overvoltage, then the analog signal output 3.9mA; If the transmitter output an positive over voltage value, the analog signal output 20.8mA.
Damping
Silicone oil filling at room temperature, the electrical damping is 0~32seconds.The smallest time constant is 0.1 seconds (range 3 is 0.4 seconds).
High temperature silicone oil filling transmitter, this value will be higher.
Performance parameter
(The zero base calibration range, reference conditions, silicone oil filling, 316L isolation diaphragm)
Accuracy (including linear, variation, repeatability total error)
Range code from 4 to 8, DP and GP transmitter;
Range code 4 to 7, HP transmitter
±0.1% of calibration range;
±0.1%+ (0.01range high limit / range)% (more than 10:1 range ratio).
Other range and model transmitter ±0.25% of calibration range
The stability
DP and GP model, the range mode 4 to 8: ±0.1% URL, 12 months;
Other range and model transmitter: 0.25% URL, 12 months.
Temperature influence:
DP and GP transmitter, measure range code from 4~8;
HP transmitter, measure range code from 4~7.
Zero error=±0.2% URL/56ºC
Total error=±(0.2% URL+0.18% calibration range)/56ºC
Other measure range and model transmitter the temperature influence times higher.
Static pressure influence
DP series transmitter
Zero error
For measure range code from 4~8, at 10 Mpa, zero error is ±0.25% URL; for measure range code is3, the error ±0.5%URL; zero error can be corrected through the zero adjustment on line.
Span error
Can be corrected to ±0.25% of input reading value / 6.8MPa
For measure range code is 3, the span error can adjusted to ±0.5%.
HP (high pressure) transmitter
Zero error
At 32Mpa static pressure, zero error is ±1% URL; Zero error can be corrected through the zero adjustment on line.
Span error
Can be corrected to ±0.25% of input reading value / 6.8MPa
Vibration impact: Frequency which is less than 200 HZ, the impact is ±0.05% URU/g at any direction.
Power impact: < 0.005%/V output range / volt.
Electromagnetic interference/radio frequency interference: according to SAMA PMC33.1, test from 20-1000 MHz, field intensity can be up to 30V/m, the output shift is less than 0.1% of span.
Installation position influence: zero drift <0.25 KPa,
When the liquid level diaphragm vertical mounting the zero drift is less than 0.25KPa,
when the liquid level diaphragm is horizontal installing the zero drift is less than 1.25KPa which plus the extended part length.
All the error can be eliminated by correction on line, so won't impact to range.
Structure specifications:
Wet parts materials
Isolation diaphragm 316L, Hastelloy C, monel or tantalum.
Drain/air valve 316L, Hastelloy C, monel.
Wet O-rings: Viton, NBR, PTFE or metal sealing ring.
Non-wet parts material:
Liquid filling: Silicon or Inertia fluid
Bolts and flange with bolts: galvanized carbon steel or 316SS;
Electric shell: Low copper aluminum;
Spraying: polyurethane (PU)
Gauge cover O ring: NBR (nitrile rubber Buna)
Process connection port:
1/4 ~ 18 NPT: Range 2~ 5, flange distance: 54 mm
1/4 ~ 18 NPT: Range 6 and 7, flange center distance: 56 mm
1/4 ~ 18 NPT: Range 8, flange center distance: 57 mm
Range code 2~ 5, Flange joint can be rotated, in order to realize the 50.8 mm,
54 mm or 57.2mm center distance.
Electrical connections
1/2~14 NPT or M20X1. 5 conduit entrance; with bolts ends
Explosion-proof class: explosion-proof Exd II BT6 or intrinsically safety Exia II ct4
Weight: if don't include accessories, the AP, DP, GP, HP models weight is 2.4kg.
Power supply voltage:
12V - 45VDC intrinsic safety products, power supply should through safety barrier firstly. (Standard is 24 VDC, if no load can work at 12VDC, with LCD header power should be not less than 16 VDC)
Products application environment
Temperature: - 20ºC~+80ºC, storage temperature: - 40ºC - + 104ºC; humidity: 0-100%
Explosion-proof products using environmental conditions:
Temperature: - 20ºC - + 70ºC; relative humidity: 5% ~ 95%.
Atmospheric pressure: 86-106 KPa
About the Supplier
This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR266912". Items marked "" are certified.
Company Profile
Hebei Xukang Meter Manufacturing Co., Ltd. (Tianjin U-ideal Instrument Co., Ltd. ) is a professional supplier and manufacturer with over two decades of experience.
Our products are primarily utilized in chemical plants, water treatment facilities, boiler level control systems, and various industrial applications. The main product lines of U-ideal (Xukang) include level gauges, level switches, sight glass flow indicators, flow meters, strainers, and filters. We have established long-term cooperation with numerous renowned companies worldwide, consistently meeting the high standards and expectations of our clients. Our fluid level switches encompass float switches, radar level switches, ultrasonic level switches, vertical and horizontal level switches, flange-mounted and threaded level switches. Our tank gauges include magnetic level gauges, glass tubular level gauges, sight glass level indicators, transparent and reflective level meters, weld glass water meters, oil level meters, fuel level controls, and indicators. Additionally, we offer drop-in type level sensors such as cable-type level sensors, pole-type level switches, hydrostatic pressure level sensors, level transmitters, capacitive level sensors, ultrasonic level transmitters, non-contact level meters, and float level transmitters. We also provide tank flange level indicators and radar RF admittance level meters. Our flow measurement instruments cover a wide range of products, including metal rotary flow meters (float flowmeters, rotameters, gas rotameters, bypass rotameters), vortex flow meters (steam vortex flowmeters), flow sensors, flow switches, liquid and gas turbine flow meters, conductive fluid electromagnetic flow meters, positive displacement flow meters (such as oval gear wheel flow meters and roots flow meters), precision vortex gas flow meters, and other flow measurement devices. Our ultrasonic measurement solutions include ultrasonic level meters, ultrasonic level sensors. Water Level Sensor Switch, Water Level Sensor, Water Level Sensor Circuit, Level Sensor Water, Liquid Level Sensor, Magnetic Level Switch, Magnetic Switch, Oil Level Sensor, Magnetic Float Switch, pressure transmitter, differential pressure transmitter.
Safety valve, pressure control valve, safety relief valve, pressure relief valve, pressure transmitters, pressure gauge, temperature gauge
Welcome to contact us, we will reply you in 24hours.
About Our Factory & Business Background
-
Business Type
- Manufacturer/Factory & Trading Company
- Address
- No. 7 Yinhai Road, Development Zone of Wei County, Xingtai, Hebei, China
-
Plant Area
- 2620 square meters
-
Number of Employees
- 17
-
Terms of Payment
- T/T, LC, D/P, Western Union, PayPal, Small-amount payment
-
International Commercial Terms(Incoterms)
- FOB, CIF, CFR, EXW
-
Average Lead Time
-
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays -
Nearest Port
- Tianjin Port
-
Minimum Order Quantity
- 1 unit
-
Supply Chain Partners
- 80
Our Production Capability & Technical Expertise
- Main Products
- Level Gauge, Flow Meter, Relex Level Gauge, Sight Glass, Strainer and Filter, Glass Level Gauge, Level Meter, Magnetic Level Gauge, Sight Glass Flow Indicator, Level Switch
-
Production Lines
- 3
-
Production Machines
- CNC lathe, Cutting machine, Drilling machine, Lathe, Machining Center, Tapping machine, Welding machine
-
QA/QC inspectors
- 1 people
-
Inspection Type for Finished Products
- Random inspection(Visual inspection & Function inspection)
-
Inspection Method for Finished Products
- Finished product checked by packing staff
-
Customization Options
- Customization from Designs, Minor Customization
-
ODM Service Available
- Yes
-
OEM Service Available
- Yes
-
R&D Engineers
- 1 people
-
Traceability of Raw Materials
- No
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2017-03-17
-
Export Year
- 9 years
-
Main Markets
- Europe, Southeast Asia/ Mideast
-
Number of Foreign Trading Staff
- 6
-
Overseas Agent/Branch
- No
-
New Products Launched in Last year
- No
FAQ
- What materials are used for the isolation diaphragm?
- The isolation diaphragm can be made of 316L stainless steel, Hastelloy C, Monel alloy, or Tantalum.
- What is the power supply requirement?
- The standard power supply is 24 VDC, with a working range of 12-45 VDC for intrinsic safety products.
- Does it support HART protocol?
- Yes, it supports HART protocol communication for remote configuration, testing, and data monitoring.
- What is the measuring range?
- The measuring range is from 100 Pa to 40 MPa, with a range ratio of 50:1.
- What are the available output signals?
- It provides 4-20mA DC analog output and digital signals based on the HART protocol.
- What is the IP rating of the transmitter?
- The transmitter has an IP67 protection rating, making it suitable for harsh industrial environments.
Send your message to this supplier
People who viewed this also viewed
-
US$298.00-300.00 / Piece
-
US$448.00-450.00 / Piece
-
US$199.00-200.00 / Piece
-
US$198.00-200.00 / Piece
-
US$160.00-169.00 / Piece
-
US$169.00-176.00 / Piece
-
US$198.00-200.00 / Piece
-
US$50.00-53.00 / Piece
-
US$60.00-70.00 / Piece
-
US$198.00-200.00 / Piece
Product Categories
Find Similar Products By Category
- Supplier Homepage
- Products
- Pressure Sensor
- Capacitance Level / Differential Pressure Transmitter Sensor
Related Categories
Hot Searches
- Pressure Switch Factories
- Pressure Sensor Factories
- Water Level Sensor Factories
- Temperature Transmitter Factories
- Level Pressure Sensor
- Used Pressure Transmitter
- Pressure Transmitter Sensor
- Flow Pressure Transmitter
- Water Pressure Level Sensor
- Pressure Sensor Bulkbuy