Electric Contact Water Level Gauge for Boiler for Pump

Product Details
Customization: Available
After-sales Service: Long-Term Online Service
Principle: Piezoelectric Type
Still deciding? Get samples of US$ 500/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Electric Contact Water Level Gauge for Boiler for Pump
  • Electric Contact Water Level Gauge for Boiler for Pump
  • Electric Contact Water Level Gauge for Boiler for Pump
  • Electric Contact Water Level Gauge for Boiler for Pump
  • Electric Contact Water Level Gauge for Boiler for Pump
  • Electric Contact Water Level Gauge for Boiler for Pump
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • other products
  • Company Profile
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
UDZ
Measurement Accuracy
±3mm
Accuracy
0.1%
Kind
Level Switch
Structure
All in One
Warranty
1 Year
Certification
CE
Material
SS304
Process Temperature
-190~425℃
Electrode Water Level Switch Type
High Pressure High Temperature
Liquid Controlled
Water, Boil Steam, Oil Level
Body Material
A105, SS304, SS316
Connection
Flange, Welding, Threaded
Switch Position Quantity
One, Two, Three, Four ......Upto 24 Nos. or More
Transport Package
Wooden Case or Carton
Specification
switch quantity and position is on order.
Trademark
Xukang
Origin
Hebei, China
HS Code
90261000
Production Capacity
5000

Packaging & Delivery

Package Size
78.00cm * 30.00cm * 40.00cm
Package Gross Weight
30.000kg

Product Description

Product Description

Summarize
Electric Contact Water Level Gauge for Boiler for Pump
The intelligent universal electric contact liquid level monitor is an electric contact type liquid level measuring, displaying and controlling instrument composed of measuring cylinder, ultra-pure ceramic electrode and display instrument.
It uses a red and green two-color light emitting tube to simulate steam (red) water (green) in the display, obviously indicating the position of the liquid level in the container, and has the function of alarm and output.

The electric contact level monitor is suitable for the level measurement and control of conductive liquids. It is mainly used for monitoring boiler bubble water level, high and low pressure heaters, deaerators, evaporators, condensers, direct current boiler starting separators and other water tank level measurement. But not suitable for flammable and explosive occasions.

Working principle

Electric Contact Water Level Gauge for Boiler for Pump


Electric Contact Water Level Gauge for Boiler for Pump

 

 

Model :XK UDZ -4S
Scale size :see below table for scale model 
Measure chamber
01 working pressure ≤6.4MPa 
02 working pressure ≤6.4MPa 
03 working pressure ≤20MPa 
04 working pressure ≤22MPa 
Install method
01 Vertical mounting      
02 Horizontal mounting      

Scale model 
Code 19A 19B 19C 19D 17A 17B 17C 17D 15A 15B 13A 13B 12A 11A 11B 11C 11D 10A 10B 9A 7A 5A
scale value 






 
+300 +250 +300 200                           +700 2200 +50    
+250 +200 +250 170 +250 1000 1700 +220                            
+180 +150 +200 160 +200 900 1600 +180 +200 1200               +500 2000 +35    
+120 +100 +150 150 +150 800 1500 +140 +150 1100 +150 900 3000               +75  
+80 +80 +100 140 +100 750 1400 +100 +100 1000 +100 850 2750 +100 1600 3000 2200 +300 1800 +20    
+50 +50 +75 130 +75 700 1300 +75 +75 900 +75 800 2500 +75 1300 2800 2000       +50 +70
+35 +35 +50 120 +50 650 1250 +50 +50 850 +50 750 2000 +50 1000 2700 1800 +150 1600 +10    
+20 +20 +30 110 +30 600 1200 +30 +30 800 +30 700 1750 +30 650 2600 1700       +25 +40
+10 +10 +15 100 +15 550 1150 +15 +15 700 +15 600 1500 +15 400 2500 1600 +50 1500 0    
0 0 0 90 0 500 1100 0 0 600 0 500 1250 0 300 2400 1500       0 0
-10 -10 -15 80 -15 450 1000 -15 -15 500 -15 450 1000 -15 200 2300 1400 0 1400 -10    
-20 -20 -30 70 -30 400 900 -30 -30 450 -30 400 750 -30 150 2200 1300       -25 -40
-35 -35 -50 60 -50 350 800 -50 -50 400 -50 300 500 -50 100 2000 1000 -50 1300 -20    
-50 -50 -75 50 -75 300 700 -75 -75 300 -75 200 250 -75 50 1000 500       -50 -70
-80 -80 -100 40 -100 250 600 -100 -100 200 -100 100 0 -100 0 0 0 -150 1000 -35    
-120 -100 -150 30 -150 200 400 -140 -150 100 -150 0                 -75  
-180 -150 -200 20 -200 100 200 -180 -200 0               -300 500 -50    
-250 -200 -250 10 -250 0 0 -220                            
-300 -250 -300 0                           -500 0      
Upper limit alarm point +180 +200 +200 150 +200 800 1500 +220 +150 1000 +150 800 2750 +100 1600 2700 1800 +500 1800 +50 +75 +70
+50 +50 +50 120 +50 750 1400 +50 +50 800 +50 700 2000 +50 1300 2500 1600 +300 1500 +35 +25 +40
Lower limit alarm point -50 -50 -50 80 -50 600 1300 -50 -50 500 -50 450 1000 -50 650 2000 1400 -300 1300 -35 -25 -40
-180 -200 -200 40 -200 500 700 -220 -150 400 -150 300 500 -100 150 1000 1000 -500 1000 -50 -75 -70
Install distance reference value  670 600 640 600 600 1000 1700 440 440 1200 440 900 3000 440 1600 2200 2200 1200 2200      
Product Parameters

Technical specification

1. Liquid resistance range: 0-500kΩ (automatic tracking)

2.Analog display: a set of color-changing light-emitting diodes (up to 19 points, up to 38 points for special specifications) display the real-time liquid level value in the form of vapor red water green with the scale scale.

3. Digital display: a one-digit symbol tube three-digit digital tube (or four-digit digital tube) displays the instant liquid level value digitally.

4. Ultra-pure ceramic electrode to secondary instrument lead length: ≤200m
Isolated output: 0 ~ 10mA (RL<1kΩ), 4 ~ 20mA (RL<500Ω) (linear)

5.Alarm output contact capacity: AC220V, 1A;
For four groups (two groups of upper and lower limits) normally open normally closed contact, special needs, for six groups and five groups, four groups of different combinations (three up three down, three up two down, two up three down, three up three down, one up three down) normally open contact.

6. Internal DC battery power supply time ≥1 hour

7. Working power supply: AC220V± 10%, 50Hz±1Hz

8.Instrument operating conditions: ambient temperature: -10ºC ~ +45ºC; Relative wet pair: ≤ 85%

9. Instrument opening size: 152+1×76+1 or 152+1×152+1mm

10.Instrument size:
Vertical: 80×160×300mm (width × height × length)                   Square: 160×160×300mm (width × height × length)
 Horizontal type: 160×80×300mm (width × height × length)       Wall mounted type: 173×225×80mm (width × height × thickness)

 
Detailed Photos

 

Electric Contact Water Level Gauge for Boiler for Pump
Electric Contact Water Level Gauge for Boiler for PumpElectric Contact Water Level Gauge for Boiler for Pump
 
other products

Electric Contact Water Level Gauge for Boiler for Pump

 
Company Profile
 

Electric Contact Water Level Gauge for Boiler for Pump

Electric Contact Water Level Gauge for Boiler for Pump
Packaging & Shipping

 Electric Contact Water Level Gauge for Boiler for Pump






 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier