Customization: | Available |
---|---|
Warranty: | One Year |
Accuracy: | ±0.2-0.5% |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Ultrasonic flow meter is designed to measure the velocity of liquid within a closed conduit. It uses the well-known transit-time measurement principle, plus our proprietary signal processing and ultrasonic transceiving technologies.
1. ultrasonic flow meter
2. DN15-DN6000
3. wide use at multiple materials of pipe
5. 10 yrs working experience foreign trade
Ultrasonic flow meter module TUF-2000M
Apply to form a complete set of system integration, water resources, energy saving, water supply and drainage, heating network monitoring projects such as flow rate, heat metering.
Features:
High precision: measurement precision is better than +/-1%
Wide measuring range: to choose different types of sensors, can realize caliber DN15 ~ DN6000mm pipe flow measurement
Powerful function:
1 way 4-20 mA output can be used as heat (thermal)flow transmitter or volume flow transmitter;
2 way OCT output can be used as heat flow switch and volume flow switch ;
3 way 4-20 mA input can be used as a data collector; 2 road 3 wire PT - 100 resistance signal input can be used as thermal meter.
Long distance transmission distance, Quick networking: RS485 bus communication, using common cable, network is very convenient and quick
1:operating power:isolation 8-36VDC
2:current: 50mA(under the condition of connection without keyboard display and alarm of buzzer)
3: signal output: one channel standard isolation RS485 output
One channel isolation 4-20mA or 0-20mA passive output.
Two channel OCT output(programmed between the pulse width(6-1000ms),default before out of factory (200ms))
4: signal input: two channel three wire system PT100 platinum resistor input loop,to make calorimeter has the function of displaying heat quantity.
Three channel 4-20mA input optional,accuracy:0.1%,has the ability to input the signals of pressure, liquid level, temperature and so on.
5:display:2*10backlit LCD,displaying instant flow rate,velocity,positive,negative,net totaliser flow rate.
6:operating: 4 keypad tactile keyboard operating
7:other functions: automatic memory the positive,negative,net totaliser or flow rate and thermal energy of the last 512 days,128 months,10years
Automatic memory the time of power turning on and off and flow rate of the last 30 times, realize to compensate by hand or automatically,read the datas through Modbus communication protocol.
8:protection level:IP57
9:transducer:clamp-on style,insertion style,flanged pipe style.
Features |
Description |
High Accuracy measuring |
Linearity: better than 0.5%, Repeatability: better than 0.2%, Accuracy: better than ±1% |
Wide measuring range |
Several types transducer for selection, measuring pipe size from DN15mm to DN6000mm |
Chinese & English menu |
Different version UFM can support Chinese or English display, easy to operate. |
High Reliability |
Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability. |
Strong Anti-interference |
Dual-balance signal differential receiver/driver circuit to avoid interference of converter, TV tower, high voltage line etc. |
Powerful Recording Function |
Automatically record the following data: 1. The totalizer data of the last 512 days/128 months/10 years 2. The time and corresponding flow meter of the last 64 times of power on and off events 3. The working status of the last 32 days |
Optional Transducer |
Model |
Measuring Range |
Liquid Temperature |
Accuracy |
|
Clamp-on Transducer |
TS-1(Small Size) |
TUF-2000SNB1 |
DN15-100mm |
-30°C~90°C |
±1% |
TM-1(Medium Size) |
TUF-2000SNB2 |
DN50-1000mm |
|||
TL-1(Large Size) |
TUF-2000SNB3 |
DN300-6000mm |
|||
High-temperature Clamp-on Transducer |
THS-1(Small Size) |
TUF-2000SNB4 |
DN15-100mm |
-30°C~160°C |
|
THM-1(Medium Size) |
TUF-2000SNB5 |
DN300-1000mm |
|||
Insertion Transducer |
TC-1(Standard) |
TUF-2000SNC1 |
DN80-6000mm |
-40°C~160°C |
|
TLC-2(Lengthen) |
TUF-2000SNC2 |
||||
Prover section |
Prover section |
TUF-2000SNG |
DN15-1000mm |
-40°C~160°C |
±0.5% |
Power Supply |
DC8-36V or AC85-264V |
||||
Input |
3 channel 4-20mA analog input |
||||
Output |
Isolation RS-485 output, 2 channel isolation OCT output: 1 channel isolation 4-20mA output (two-wire system) |
||||
Communication Protocols |
Compatible with METER-BUS, MODBUS, Fuji extended protocol and general water meter protocol. |