Customization: | Available |
---|---|
Warranty: | One Year |
Accuracy: | ±0.2-0.5% |
Still deciding? Get samples of US$ 99/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Ultrasonic flow meter is designed to measure the velocity of liquid within a closed conduit.
Items | Performance& Index | |
Main | Drinciple | Low voltage, multipulse |
Accuracy | 1% or better repeatabili ty of 0.5% measuring perlod: 500ms | |
Backlit lcd display shows instantane ous flow/calory and accumulated flow/calory, flowrate, time etc. | ||
Output Signals | Electric current output of 420mA or 020mA, impedance of 01K, precision of 0.1% | |
OCToutputpositive/negtive/net flow or integrating flowrate pulse signal or instantane flowrate Frequency signalfrom19999HZ | ||
After the electric appliances: can output 20 source signals(such as have no signal, antitoflow etc) | ||
The mschine of buzzer can send out to report to the voice according to the constiution(if the discharge lead greatly, too small | ||
Imput Signals | Five electric current signals imput(temperatare, pressure, fiwid level), one engine for dual purose | |
Automatic memory of a accumulative flow of last 64 days 64 months, 5years | ||
The automatic memory is exto telephone and cut the power time and discharges 64 times, can carry on the artificial or repair the quantity automatically, reducing the customer discharge loss | ||
Automatic record the woking condition of flow meter in last 64 days | ||
The date connects: a factory install for 232 ways of the RSchoosing to go together with the RS232/the RS485 conversion | ||
Programmable batch /ration controller | ||
Cable for sole use | Style: SEVY752 sheild a single root can lengthen to 500 meters(exceed a contact), support and should notice the electric cable and dont proceed together with the high pressure electric cable at the sametime, averting from to chang the machine of as far as possible | |
Ipe condition | Pipe materids | Steel, stainless steel, cast iron, cerrent pipe, copper, PVC, aluminium, glass stell etc. |
Internal diameter | 15mm6000mm | |
Straight pipeline | Stansducer should be installed as follows: upsteam 10D, downsteam 5D and 30D away from the pump exit | |
Measuring | Style | Water, seawater, sewage, PH liquids, alcohol, beer, oils etc. can conduct the even liquid of the one of a wave |
Semperature | 0160 | |
Turbidity | Below ≤ 10000ppm | |
Flowrate | 0± 30m/s | |
Flowdirection | Positive and negative to double to calculate, and calurlate the clean dischage or calorieses | |
Operating condition | Temperature | Main engine3080 |
Flow transducer40160 | ||
Humidity | Main engine: 85%RH | |
Flow transducer can under water of depth lower than 3m | ||
Power source | AC220V o rDC836V or AC730V | |
Power consumption | 2W | |
Weight | F1: 2.5Kg p F2: 7Kg S: 1.5Kg |
Technical Data hand held type ultrasonic flowmeter |
||
Flow Meter |
Power |
AC220 (100-240V), 50/60HZ, 0.6A |
Power Supply |
Build-in Battery (> 12 hour) |
|
Output |
OCT, RS232, Data Storage Device |
|
Error |
± 1.0%R (Flow Rate> 0.5m/s |
|
± 0.005m/s (Flow Rate< 0.5m/s) |
||
Sensitivity |
Minimum Flow Rate: 0.01m/s |
|
Repeatability |
0.2%R |
|
Size & Weight |
100*204*34, < 0.5kg |
|
Transducer |
Pipe Size |
S Type: 15-50mm M Type: 40-1000mm L Type: 1000-4570mm |
Temperature |
Standard: -40-121° C, High Temperature: -40-250° C |
|
Type of Transducers |
L Type, S Type, M Type, High Temperature Type |
|
Pipe Material |
Various kinds of material |
|
Size & Weight |
S type: 42*25*25mm, < 0.2kg M type: 60*43*43mm, < 0.5kg L type: 80*53*53, < 1.0kg |