Gold Member Since 2013
Audited Supplier
Hebei Xukang Meter Manufacturing Co., Ltd.

Mass Flow Measurements of Liquids, Liquid Flow Meter Sensor, Water Flow Meter manufacturer / supplier in China, offering Mass Flow Measurements of Liquids-Mass Air Flow Meter-, Yg43h Pneumatic Regulator, High Sensitivity Steam Pressure Reducing Valve, Ultrasonic Level Meter Explosion-Proof Type and so on.

(/ )

Supplier Homepage Product mass flowmeter Coriolis Mass Flowmeter Mass Flow Measurements of Liquids-Mass Air Flow Meter-

Mass Flow Measurements of Liquids-Mass Air Flow Meter-

FOB Price: US $1,200 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $1,200/ Piece
Get Latest Price
Production Capacity: 6000 PCS/Month
Transport Package: Wooden Case or Carton
Payment Terms: L/C, T/T, D/P, Paypal, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: LWGY
  • Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
  • Sensor: Tube/Flange
  • Type: Coriolis Mass Flow Meter
  • Measuring Principle: Atomic Physics
  • Flow Fluid Measured: Liquid, Air, Solid Flow
  • Indicate: Flow Rate, Total Flow, Density, Temperature
  • Ex-Proof: Intrinsic Safety/ Explosion-Proof
  • Trademark: U-ideal
  • Origin: Tianjin, China
  • Accuracy: ±0.2%~±0.15%, ±0.2-0.5%
  • Size: Dn1.5~Dn200
  • Application: Industrial Production
  • Measuring Media: Liquid
  • Certification: JIS, DIN, ANS, GB, CE, UL, RoHS, ISO
  • Output Signal: 4-20mA, Pulse, RS485, Hart
  • Fluid Types: Two-Phase Flow, Three-Phase Flow
  • LCD: Yes/No
  • Specification: sgs, iso
  • HS Code: 90261000
Product Description
Mass Flow Measurements of Liquids-Mass Air Flow Meter-
I. Main technical parameters
(1) Measurement scope: 2kg/h~500t/h
(2) Accuracy: ± 0.2%~± 0.15%
(3) Work pressure: (0~32) MPa (in case of other high pressure, it must be of special order)
(4) Medium temperature: -50º C~ +350º C,
Measurement accuracy: ± 1º C
(5) Environment temperature: -20º C ~ +70º C
(6) Measurement medium: Liquid, gas, solid, or two phases and three phases mixed fluid
(7) Output signal:
4-20mA current signal of flow, with load resistance ≤ 500Ω
0-10kHz frequency signal of flow.
RS485 Communication protocol
Hart protocol
(8) Power supply voltage: 24VDC
(9) Measurement of measuring pipe: 316L stainless steel
(10) Response time: 0.1s~5s, adjustable
(11) Explosion-proof grade: Ex(ib)II BT2-T5
ModelDNMeasurement scope ( kg/h )Work Pressure  ( MPa )Connection type (mm)
DMF-1-1-AB1.50~40~32Weld Joints Φ6×1.5
DMF-1-1-A30~400~32Weld Joints Φ6×1.5
DMF-1-1-B60~1000~25Weld Joints Φ10×2
DMF-1-2-A80~2000~20Weld Joints Φ10×1







                                                                                                                                                                                                
ModelDNMeasurement scope (kg/h)Work Pressure (MPa)Connection Type(mm)

DMF-1-3-A
120~5000~4Weld Joints Φ18×3
120~5000~25Weld Joints Φ20×4

DMF-1-3-B
140~10000~4Weld Joints Φ18×2
140~10000~25Weld Joints Φ20×3

DMF-1-4
160~30000~4Weld Joints Φ18×1
160~30000~25Weld Joints Φ20×2











ModelDNMeasurement scope (t/h)Work Pressure (MPa)Connection Type(mm)
DMF-1-5-A250-100~4Flange 25
DMF-1-5-B400-200~4Flange 40
DMF-1-6-A500-300~4Flange 50
DMF-1-6-AB650-500~4Flange 65
DMF-1-6-B800-1000~4Flange 80
DMF-1-6-C1000-1500~4Flange 100
DMF-1-6-D1500-3000~2Flange 150
DMF-1-6-E2000-5000~2Flange 150